Untreated filter 1 (High temperature & Low RH) Experiment 1. Temperature: 30+2 C Pressure drop Relative Humidity Experiment Control Removal Eff. Time (mm) (in. H20) (%) (PFU/mL) (PFU/mL) (%) 30 0.3 33 3550 101000 96.49 60 0.3 35 6900 74500 90.74 90 0.3 40 3950 102500 96.15 120 0.3 39 4850 119000 95.92 Experiment 2. Temperature: 30+2 C 30 0.3 36 2850 87500 96.74 60 0.2 35 3100 137500 97.75 90 0.3 33 6950 50000 86.10 120 0.3 35 8650 90000 90.39 Experiment 3. Temperature: 30+2 C 30 0.3 40 580 14000 95.86 60 0.3 39 1470 18000 91.83 90 0.3 43 1135 14000 91.89 120 0.3 35 825 14500 94.31 Experiment 4. Temperature: 30+2 C 30 0.4 27 2850 155000 98.16 60 0.2 33 5450 90000 93.94 90 0.3 34 4200 134500 96.88 120 0.3 30 5550 35000 84.14 Experiment 5. Temperature: 30+2 C 30 0.2 41 3400 99500 96.58 60 0.2 40 3400 80500 95.78 90 0.2 33 3000 112000 97.32 120 0.2 37 6000 97000 93.80