82 throughout the entire range of the design depth. The STA operates over a relatively narrow range from 1.5 to 3.5 feet, as stated previously. 100% 90% 80% 70% g 60% S50% .E 40% II v 30% 20% 10% 0% -- EAASR - STA 3/4 0 2 4 6 8 10 12 Mean depth, ft. Figure 5-2. Mean Annual Depths from SC STA Scenario The HRT profile reflects the difference in depth profiles (Figure 5-3). The EAASR operates under a large range of HRT's. The HRT distribution shows STA 3/4 operating in the within the normal range of STAs, 14 to 21 days, for approximately 19% of the years for <= 14 days and 50% of the years for <= 21 days. The remaining 50 percent of HRT are above this range, again indicating the STA may be able to receive more hydraulic loading.