Table A.9 Results of Oynaflect Tests on I-10C (Madison County) Temperature (F): Air = 82 Pavement Surface = 99 Mid-Pavement = 106 Site Mi 1 e Type of Measured Deflections (mils) for Sensor Positions* No. Post No. Data j 2 3 4 5 6 7 8 9 10 1 32.071 Std 0.46 0.30 0.22 0.18 0.15 1 32.071 Mod 0.70 0.43 0.29 0.18 0.15 1 32.071 Std 0.40 0.28 0.22 0.18 0.15 (OWP) * Sensor positions correspond to the modified array in Figure 4.2