420 UNIV. OF FLORIDA CIVIL ENG. DEPT.- DR. B.E. RUTH FILE NAME: PAVEMENT-SUBGRADE MATERIALS CHARACTERIZATION FILE NUMBER: 245-D51 RECORD OF DILATCETER TEST NO. 3 USING DATA REDUCTION PROCEDURES IN MARCHETTI (ASCE,J-GED,MARCH 80) KO IN SANDS DETERMINED USING SCHPERTMANN METHOD (1983) PHI ANGLE CALCULATION BASED ON DURGUNOGLU AND MITCHELL (ASCE,RALEIGH CONF,JUNE 75) PHI ANGLE NORMALIZED TO 2.72 BARS USING BALIGH'S EXPRESSION (ASCE,J-GED,NOV 76) MODIFIED MAYNE AND KULHAWY FORMULA USED FOR OCR IN SANDS (ASCE,J-GED,JUNE 82) LOCATION: SR 15A (MARTIN CO.) TEST SITE #5.0 PERFORMED DATE: 04-29-86 BY: DAVE/KWASI/ED CALIBRATION INFORMATION: DELTA A 0.17 BARS DELTA B = 0.35 BARS GAGE 0 = 0.05 BARS GWT DEPTH= 1.65 M ROD DIA.- 3.70 M FR.RED.DIA.= 3.70 CM ROD WT.= 6.50 KG/M DELTA/PHI= 0.50 1 BAR = 1.019 KG/CM2 = 1.044 TSF = 14.51 PSI BLADE T=13.70 MM ANALYSIS USES H20 UNIT WEIGHT = 1.000 T/M3 ED ID KD (BAR) ***** ***** ***** 761. 768. 681. 389. 68. 14. 7. 14. 8. 25. 353. 313. 32. 58. 633. 622. 356. 382. 1030. 53.75 77.14 36.13 22.08 4.26 3.31 3.02 2.79 2.82 1.27 3.00 8.06 2.51 1.28 6.50 14.02 3.40 6.35 19.65 UO GAMMA SV (BAR) (T/M3) (BAR) ****** ****** ****** 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.017 0.036 0.056 0.076 0.095 0.115 0.134 0.154 0.174 0.193 0.213 0.233 2.000 2.150 2.000 2.000 1.700 1.600 1.500 1.600 1.500 1.600 1.800 1.900 1.600 1.700 1.900 2.000 1.900 1.900 2.150 0.087 0.129 0.168 0.208 0.241 0.272 0.302 0.317 0.326 0.338 0.354 0.372 0.383 PC OCR KO (BAR) ***** ***** ***** 55.55 18.88 10.79 0.64 0.60 0.57 0.53 0.56 0.21 0.27 2.86 0.55 **** 51.93 2.66 2.19 1.90 1.68 1.71 0.61 0.77 7.71 1.42 0.397 0.415 0.434 6.46 14.86 1.40 0.452 0.470 1.89 4.02 0.73 0.492 18.29 37.15 2.29 END OF SOUNDING TEST NO. 3 z (M) ***** CU PHI (BAR) (DEG) **** ***** M (BAR) ***** THRUST (KG) **M ** 7335. 6835. 3650. 1670. 560. 310. 255. 270. 380. 450. 1225. 1405. 630. 1430. 5430. 5650. 3165. 2180. 5415. A (BAR) **** 5.60 10.90 6.90 5.00 1.00 0.80 0.80 0.80 0.85 0.40 1.50 3.40 1.00 0.60 3.60 7.00 2.10 3.60 11.20 B (BAR) 27.00 32.50 26.10 16.20 3.40 1.70 1.50 1.70 1.60 1.60 11.70 12.50 2.40 2.70 21.50 24.60 12.40 14.60 40.00 0.112 0.111 0.106 0.111 SOIL TYPE SAND SILTY SAND SILTY SAND SILTY SAND SILTY SAND SILTY CLAY MUD SILTY CLAY MUD SANDY SILT SAND SILTY SAND SILT SILTY SAND SAND SILTY SAND SAND SAND SILTY SAND 3113.2 46.2 3405.7 43.7 2529.2 39.0 1264.6 37.1 116.3 18.9 8.3 16.5 10.1 35.9 21.1 42.0 512.5 39.0 723.0 35.7 48.9 1346.3 45.7 1755.1 557.1 42.0 804.0 42.9 3234.9