Table 5.3 -- EDX Measurements Alloy Heat Treatment Ni Gamma Prime Mo A1 Ni Gamma Mo A1 197 Solution Heat Treated and Quenched (SHTQ) 77.2 3.8 19.0 78.0 16.7 5.0 SHTQ, 760 C for 100 hrs 85.0 2.1 12.9 88.0 9.9 1.5 SHTQ, 810 C for 100 hrs 76.0 5.0 19.0 76.0 17.0 7.0 SHTQ, 870 C for 1 hr 77.0 4.8 18.2 78.1 15.6 6.3 SHTQ, 870 C for 100 hrs 78.0 5.4 16.6 80.5 16.3 3.2 209 SHTQ Not Analyzed 77.0 16.2 7.1 SHTQ, 760 C for 100 hrs 77.1 4.6 18.3 75.0 18.1 6.9 SHTQ, 810 C for 100 hrs 77.0 5.0 18.0 77.7 16.5 5.8 SHTQ, 870 C for 1 hr 76.3 5.7 18.0 77.0 19.0 4.0 SHTQ, 870 C for 100 hrs 77.2 3.6 19.2 80.5 16.2 3.4 //17 SHTQ, 870 C for 1 hr 76.2 6.3 17.5 76.1 17.9 6.0 168