58 measurements were made with a General Electric horizonal main protractor diffractometer using Ni filtered Cu K-alpha radiation. Data thus generated were also used to measure the lattice mismatch between the gamma and gamma prime phase in the RSR alloys. Rockwell C microhardness measurements were made on most of the RSR aged alloys. Six hardness values from each sample were recorded.