Table 11. Performance of five nonlethal electric rodent barrier designs. % Lower Upper % No. No. Successful electrode electrode Attempts Barrier design crossings attempts attempts shocks shocks shocked Prototypea 2 47 4.3 37 5 89.4 Modified prototype 3 45 6.7 30 15 100.0 Plastic net Ic 3 42 7.3 40 1 97.6 Plastic net IId 5 37 13.5 36 3 105.4* Plastic net IIIe 1 32 3.1 28 1 110.4* a Twenty-five millimeter chicken wire (35 cm high) with two ground and two active electrodes spaced 15 cm apart at top. b Same as above with lower ground wire excluded. c Twenty-five millimeter plastic fish net with one ground wire and three active electrodes spaced 30 cm apart. d Three electrodes interspaced with three ground wires at a distance of 37 mm. e Three electrodes 5 cm in front of net interspersed with two ground wires spaced 5 cm apart vertically. * Exceeded 100 percent when more than one shock was received by rats per each attempt to cross.